Our modules for CTA (Air Treatment Unit)
Airflow: 2,000-125,000 m³/h Airovision is a modular construction that can be fully customised to provide the necessary performance for any application such as leisure and event complexes, theatres, museums, libraries, corporate and institutional offices, shopping centres, supermarkets, department stores and educational establishments, as well as oil drilling rigs, airports and cruise ships. Also ideal for healthcare facilities and industries with strict hygiene requirements. Environmentally friendly Robust High corrosion resistance Easy to maintain Features and benefits Environmentally friendly No painting required after the production process 100% recyclable components Low energy consumption due to optimised component selection High efficiency heat recovery devices available Rigid construction Carrier profile steel frame construction Panels with 60 mm thick thermal insulation Robust base frame made of galvanised square steel profile High corrosion resistance Filters held in 316L stainless steel frames Corrosion protection available Inner and outer panels made of high quality pre-painted stainless steel sheets High quality integrated components Heat recovery wheels (optional if absorption) Silent high efficiency centrifugal fans (optional) Aluminium dampers (optional) Easy maintenance Easy to remove filters Large access doors Smooth interior surfaces Technical specifications Heat transfer factor class T2 Thermal bridge factor TB2 Tightness class L2 Mechanical strength class D1 Filter bypass leakage class F9
Recommended use The AHU is used, depending on the model chosen, for - the transport and air conditioning of air in and outside buildings where human beings stay - to create the desired indoor air quality in a space occupied by human beings - creating acceptable comfort or desired working conditions - Depending on the type of CTA, air conditioning is mainly carried out by: o Air change o Regulation of ambient temperature and humidity o Filtration of air normally polluted air o Filtration to specific requirements (clean room, etc.) The CTA is suitable for - operation within the agreed design data ranges - an ambient temperature range of -20°C to +60°C over the installation site; if electrical/electronic components are installed outside the AHU, then the maximum temperature is +40°C - a minimum transport air temperature of -20°C (if applicable, frost protection measures must be installed) - a maximum transport air temperature of 60°C - inside the AHU, at motors and other electrical/electronic components, the maximum temperature is 40°C
The VERSO-P and VERSO-R dual-flow units are one-piece units, made up of three splittable elements; two completely symmetrical sections including fans and filters and a central section housing the heat exchanger. The heat exchanger is rotary (-R) or plate (-P) type. Accessories such as coils and dampers are mounted outside the unit. The VERSO-S single flow unit is made up of two basic elements (fan section and filter section) between which hot and cold coil sections can be inserted. Sizing: The VERSO range of units covers a flow rate range of 1,000 to 26,000m3/h with a maximum static pressure of 900 Pa. They are available in 8 sizes, thus making it possible to respond precisely to the needs of the user.